Key result
New LC-MS/MS method simultaneously quantifies plasma NOACs with limits <1 μg/L.
Why the study?
Assessment of anticoagulant intensities of NOACs is required in various clinical circumstances despite their fixed dosing without routine monitoring.
A rapid and reliable LC-MS/MS method was successfully developed and validated for the simultaneous quantification of apixaban, dabigatran, and rivaroxaban in human plasma.
Answers are grounded in this paper and cite their sources.
Enables multiplexed NOAC quantification in plasma labs; leaves open prospective validation for clinical therapeutic monitoring.
BACKGROUND: The non-vitamin K antagonist oral anticoagulants (NOACs) apixaban, dabigatran, and rivaroxaban are being administered in fixed doses without routine monitoring of anticoagulant activities. Despite this key advantage over vitamin K antagonists (VKAs), assessment of anticoagulant intensities is required in various clinical circumstances. We developed a multi-analyte approach for mass spectrometric analysis of NOACs in human plasma. METHODS: Plasma samples were precipitated with acetonitrile. Separation was achieved by liquid chromatography using a C18 column and a gradient elution within a run time of 2.5 min. Positive electrospray ionization was used and ion transitions monitored by a triple quadrupole mass spectrometer. Stable-isotope-labeled analogues of analytes were employed as internal standards for quantitative analysis. Certified external quality control samples were obtained for external validation. RESULTS: For all analytes, linearity could be demonstrated over the concentration range of 1-500 μg/L (R2>0.999), and the calculated limits of quantification were <1 μg/L. Results for inter- and intra-day assay precision and trueness were obtained using internal quality control samples and remained within the acceptance criterion of ±15%. External quality control samples were measured at the specified nominal values with inter- and intra-day precisions <14%. Matrix effects were fully compensated by co-eluting internal standards, which in turn did not relevantly influence ionization efficiency. CONCLUSIONS: The method enables rapid and reliable simultaneous determination of NOAC concentrations in human plasma. It was successfully introduced into clinical practice; a case with rivaroxaban overdose is presented to exemplify the method's applicability.
No takes yet. Share an insight, caveat, or question.
Blaich et al. (2015) studied NOAC concentration measurement. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) was evaluated on Linearity, limits of quantification, precision, and trueness. A developed liquid chromatography-tandem mass spectrometry method for simultaneous determination of NOACs in human plasma demonstrated linearity over 1-500 μg/L with limits of quantification <1 μg/L.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: