The output voltage of power electronic converters is a very important quantity for dynamic control of power electronic systems. In electrical drives without electromechanical position or speed sensor, the terminal reference voltage is used to obtain the rotor position. Dead-time effects and semiconductor voltage drop lead to distortion in the actual output voltage and degrade the control performance when the back electromotive force magnitude is low. Thus, for stable low-speed operation, output voltage sensing becomes necessary. Due to the switching nature of power electronic systems, this is not a trivial task, especially when instantaneous measurement of the terminal voltage is required. In this paper, an instantaneous switching-period average voltage sensing technique is proposed that utilizes a combined approach of oversampling and filtering. Based on the theoretical analysis of the sampling- and filter-induced measurement distortion, a general solution for an optimal filter design is derived. The additional sensing circuit is integrated into the low-side gate driver of the converter outputs. This paper includes details about the hardware implementation and extensive verification measurements.