Key result
Adding a 1D CNN reduces remote heart rate measurement error ~29% versus POS algorithm alone.
Why the study?
Motion artifact due to illumination changes and subject movement remains a major problem for remote photoplethysmography signal quality in real conditions.
A 1D CNN-based signal quality classification and compensation network improves the accuracy of non-contact heart rate measurement via remote photoplethysmography.
May enhance remote photoplethysmography accuracy in controlled settings; leaves open clinical validation before practice adoption.
Remote photoplethysmography (rPPG) for non-contact heart rate measurement has been widely developed and shows good development. However, motion artifact due to changes in illumination and subject movement is still the main problem. Especially when measurements are taken in real conditions. In these conditions, it will be vulnerable to rPPG signal readings with poor signal quality. So, in this paper, it is proposed to classify the signal quality using one dimensional convolutional neural network (1D CNN). The classification is carried out based on the extraction of the temporal features of the rPPG signal that has been obtained from the plane orthogonal to skin algorithm and the magnitude of the subject's movement when measured. The classification results are entered into a compensated network if the signal obtained shows moderate quality. The compensated network will provide a more accurate estimate of hr value. The test was carried out using a dataset of 10 subjects, each measured with 3 different types of illumination. In the experiments conducted, the system's performance showed an improvement compared to the POS algorithm alone. The experiment found that the mean absolute error measurement was 2.78, and the mean error was relative at 3.67%.
No takes yet. Share an insight, caveat, or question.
Firmansyah et al. (2022) studied Heart rate measurement (n=30). 1D Convolutional Neural Network (POS + 1DCNN) vs. Plane Orthogonal to Skin (POS) algorithm alone was evaluated on Mean Absolute Error (MAE). The addition of a 1D convolutional neural network for signal quality classification and compensation reduced the mean absolute error of remote heart rate measurement from 3.89 to 2.78 compared to the POS algorithm alone.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:
More from Indonesian Journal of Electrical Engineering and Computer Science