Shortcomings in the dynamic range and the frequency bandwidth of current diagnostic methods mean that measurement of the time-resolved discharge current in a long air gap discharge is still a serious problem. This work presents data from a novel discharge current sensor that takes the parameters required to determine the accuracy of the current measurement into account. The design of a coaxial current sensor with ±0.7% accuracy and a bandwidth of 75 MHz is presented. A digital optical fiber transmission system with a bandwidth that exceeds 100 MHz is used to transmit the signal. To demonstrate the efficiency of the whole system, experiments using a rod-plane discharge geometry with 2 m and 4 m air gap lengths are performed to analyze the measured current data in comparison with that taken from synchronized high-speed photographs. The results demonstrate that the investigated experimental set-up improves substantially the understanding of the fundamental mechanisms of long air gap discharges.
No takes yet. Share an insight, caveat, or question.
Yue et al. (2013) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: