Key result
Prone multi-beam IMRT is linked to improved dose homogeneity versus prone wedged and supine techniques.
Why the study?
Early stage breast cancer patients are long-term survivors and techniques that may lower acute and late radiotherapy-induced toxicity are crucial to identify.
Does multi-beam IMRT improve dose homogeneity and reduce organ-at-risk exposure compared to wedged tangential fields in prone and supine positions for whole-breast irradiation?
Observational (n=18)
No
Does multi-beam IMRT improve dose homogeneity and reduce organ-at-risk exposure compared to wedged tangential fields in prone and supine positions for whole-breast irradiation?
Prone IMRT provides superior target dose distribution and organ-at-risk sparing for right-sided breast cancer and left-sided breast cancer with larger breasts, while MB-IMRT is the treatment of choice in the supine position.
Answers are grounded in this paper and cite their sources.
Small planning study leaves open optimal WBI technique and position; prospective trials needed before clinical adoption.
BACKGROUND: Early stage breast cancer patients are long-term survivors and finding techniques that may lower acute and late radiotherapy-induced toxicity is crucial. We compared dosimetry of wedged tangential fields (W-TF), tangential field intensity-modulated radiotherapy (TF-IMRT) and multi-beam IMRT (MB-IMRT) in prone and supine positions for whole-breast irradiation (WBI). METHODS: MB-IMRT, TF-IMRT and W-TF treatment plans in prone and supine positions were generated for 18 unselected breast cancer patients. The median prescription dose to the optimized planning target volume (PTVoptim) was 50 Gy in 25 fractions. Dose-volume parameters and indices of conformity were calculated for the PTVoptim and organs-at-risk. RESULTS: Prone MB-IMRT achieved (p<0.01) the best dose homogeneity compared to WTF in the prone position and WTF and MB-IMRT in the supine position. Prone IMRT scored better for all dose indices. MB-IMRT lowered lung and heart dose (p<0.05) in supine position, however the lowest ipsilateral lung doses (p<0.001) were in prone position. In left-sided breast cancer patients population averages for heart sparing by radiation dose was better in prone position; though non-significant. For patients with a PTVoptim volume ≥600 cc heart dose was consistently lower in prone position; while for patients with smaller breasts heart dose metrics were comparable or worse compared to supine MB-IMRT. Doses to the contralateral breast were similar regardless of position or technique. Dosimetry of prone MB-IMRT and prone TF-IMRT differed slightly. CONCLUSIONS: MB-IMRT is the treatment of choice in supine position. Prone IMRT is superior to any supine treatment for right-sided breast cancer patients and left-sided breast cancer patients with larger breasts by obtaining better conformity indices, target dose distribution and sparing of the organs-at-risk. The influence of treatment techniques in prone position is less pronounced; moreover dosimetric differences between TF-IMRT and MB-IMRT are rather small.
No takes yet. Share an insight, caveat, or question.
Mulliez et al. (2013) conducted an observational in Early stage breast cancer (n=18). Multi-beam intensity-modulated radiotherapy (MB-IMRT) vs. Wedged tangential fields (W-TF) and Tangential field IMRT (TF-IMRT) was evaluated on Dose homogeneity (p=<0.01). Prone multi-beam intensity-modulated radiotherapy significantly improved dose homogeneity compared to prone wedged tangential fields and supine techniques (p<0.01).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: