Key result
Balloon-expandable valve-in-valve replacement linked to ~22% lower 5-year mortality and fewer strokes vs native TAVR.
Why the study?
Aortic valve-in-valve replacement is approved for high-risk patients based on small series with short-term follow-up, lacking large-scale mid-term outcome data.
Does balloon-expandable aortic valve-in-valve replacement improve 5-year death and stroke compared to native TAVR in patients requiring transcatheter valve therapy?
Cohort (n=27,276)
Yes
Does balloon-expandable aortic valve-in-valve replacement improve 5-year death and stroke compared to native TAVR in patients requiring transcatheter valve therapy?
Answers are grounded in this paper and cite their sources.
Balloon-expandable aortic valve-in-valve replacement demonstrates lower 5-year rates of death and stroke compared to native TAVR, supporting its safety and durability.
BACKGROUND: Aortic valve-in-valve (AViV) replacement for is approved for patients with degenerated surgical valves at high or prohibitive surgical risk, mostly on the basis of small series with short-term follow-up. OBJECTIVES: The aim of this study was to analyze the outcomes of AViV therapy using contemporary balloon-expandable valves (BEVs) in a large series with mid-term outcomes. METHODS: BEV AViV patients (June 2015 to December 2023) in the Society for Thoracic Surgeons (STS)/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry were propensity matched to native transcatheter aortic valve replacement (TAVR) patients. Primary analysis included death and stroke at 5 years. Comparisons were also made on the basis of STS score, BEV subtype, and stented vs stentless index surgical valve type. RESULTS: In total, 14,474 AViV patients were matched to 385,556 TAVR patients (13,638 pairs). The mean age was 74 years, and the mean STS Predicted Risk of Mortality was 6.1%. Emergency cardiac surgery (0.2%) and bioprosthetic valve fracture (22%) were infrequent. Death (43.1% vs 55.2%; P < 0.001), stroke (10.5% vs 11.8%; P < 0.001), and their composite were lower for AViV compared with TAVR at 5 years with similar findings at each STS tertile. The SAPIEN 3 Ultra RESILIA device demonstrated lower discharge echo gradients for all sizes (20 mm, 19.4 mm Hg vs 23.8 mm Hg; 23 mm, 15.1 mm Hg vs 19.2 mm Hg; 26 mm, 12.1 mm Hg vs 15.1 mm Hg; and 29 mm, 8.6 mm Hg vs 12.1 mm Hg). There was no difference in death or stroke at 5 years for stentless vs stented surgical valves (42.9% vs 46.0%; P = 0.12). CONCLUSIONS: This large, real-world analysis confirms the safety and durability of AViV compared with TAVR at all surgical risk levels at mid-term follow-up. Consideration may be given to broadening the indication for AViV.
No takes yet. Share an insight, caveat, or question.
Krishnaswamy et al. (2025) conducted a cohort in Degenerated surgical aortic valves (n=27,276). Balloon-expandable aortic valve-in-valve (AViV) replacement vs. Native transcatheter aortic valve replacement (TAVR) was evaluated on Death at 5 years (p=<0.001). Balloon-expandable aortic valve-in-valve replacement was associated with lower rates of death (43.1% vs 55.2%; P<0.001) and stroke (10.5% vs 11.8%; P<0.001) at 5 years compared with native TAVR.