The authors present a novel control method for forced commutated cycloconverters (PWM cycloconverters). Using this control method the sinusoidal input and output current waveforms and the unity input displacement factor can be obtained. Moreover, the compensation of the asymmetrical and/or harmonic contaminated input source voltages is easily realized. This control method allows the input displacement factor not to be controllable, but to be fixed at approximately unity. Since a unity input displacement factor is desirable for motordrive use for the PWM cycloconverters, this constraint is not a new obstacle. Feasibility of the proposed control method is verified by simulations and experiments.>
No takes yet. Share an insight, caveat, or question.
Ishiguro et al. (1991) studied this question.