Continuous column study demonstrates effective uranium removal using phosphonated polyethylenimine across varying flow rates and bed heights, highlighting its potential for nuclear wastewater...
A continuous fixed-bed adsorption study was carried out by using phosphonated cross-linked polyethylenimine as an adsorbent for the removal of uranium (U) from aqueous solutions. The effect of inlet metal ion concentration (40, 70, and 100 mg L −1 ), feed flow rate (1, 2, and 3 mL min −1 ), and polymer bed height (2.5, 3.2 and 4.5 cm) on the breakthrough characteristics of the fixed-bed adsorption system at pH 2 were studied. The results showed that the breakthrough time appeared to increase with increase of bed height but decreased with increase of both influent U concentration and flow rate. Modelling of the dynamics of the fixed-bed adsorption process was studied and the application of different models to describe the breakthrough curves showed that the Thomas and Yoon–Nelson model gave better results for the operating conditions.
No takes yet. Share an insight, caveat, or question.
Saad et al. (2014) studied this question.