Reports on the design, fabrication, and testing of an electrostatic microactuator for a magnetic hard disk drive (HDD) tracking servo. The design requirements for a microactuator are investigated. These include high Z-directional stiffness, low in-plane stiffness, high structural aspect ratio, large output force, high area efficiency, low cost, and mass batch production. An area-efficient rotary microactuator design was devised, and microactuators were successfully fabricated using innovative processing technologies. The microactuator has a structural thickness of 40 /spl mu/m with a minimum gap/structure width of approximately 2 /spl mu/m. Its frequency response was measured and it was determined that it can be modeled as a second-order linear system, up to the 26-kHz frequency range. Moreover, the microactuator will enable the design of a servo system that exceeds a 5-kHz servo bandwidth, which is adequate to achieve a track density of more than 25 kilotrack per inch (kTPI). The microactuator/slider assembly was also tested on a spinning disk, with its position controlled by a PID controller using the magnetic position error signal written on the disk. An accuracy of about 0.05 /spl mu/m was observed when the servo controller was turned on. Continuous-time dual-stage servos were designed and simulated using the /spl mu/-synthesis technique. A sequentially designed SISO and a MIMO control design method have been shown to be capable of meeting prescribed uncertainty and performance specifications.
No takes yet. Share an insight, caveat, or question.
Hirano et al. (1998) studied this question.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: