This paper presents the evaluation of scale effects for the hydraulic conductivity, k, of a sand. Data were obtained using several methods at a site that was densely instrumented with piezometers within an area of about 100 m × 100 m. The 3.13.6 m thick sand deposit rests on a thick, nonfissured Champlain Sea clay deposit. At the small scale, local k values were obtained from the grain-size curves of sand samples and also from ground-penetrating radar surveys. At the intermediate scale, k values were obtained from field variable-head tests using piezometers. At the large scale, k values were obtained from pumping-test drawdowns in steady-state conditions. In this sand aquifer, the careful evaluations at three scales gave similar narrow distributions for the hydraulic conductivity, and therefore no scale effect is evidenced.
No takes yet. Share an insight, caveat, or question.
Chapuis et al. (2005) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: