Answers are grounded in this paper and cite their sources.
The time-harmonic solution for the anomalous vector potential due to a conducting permeable sphere in the field of a current-carrying loop is used to derive the corresponding step response. The step response is then used to obtain analytical expressions for the voltage induced in a second loop due to a chosen exciting current pulse train. The voltage induced in an actual system of coils is obtained by superposition. The effect of the measurement system is included in the analysis in order to experimentally verify the model. Measured responses of a number of aluminum and steel spheres at various distances from the coils are compared with theoretical predictions. The agreement between the two is generally good.
No takes yet. Share an insight, caveat, or question.
Das et al. (1984) studied this question.