Although the galvanic distortion due to local, near-surface inhomogeneities is frequency-independent, its effect on the magnetotelluric data becomes, in a 3-D structure, frequency-dependent. Therefore, both the apparent resistivity and the phase responses are disturbed, and a correction should be carried out prior to the 3-D interpretation in order to retrieve the 3-D regional impedance tensor. In many cases, the structure is 2-D for depths corresponding to a first range of periods and 3-D for longer periods (called 2-D/3-D). For these cases, a simple method which allows us to retrieve the 3-D regional impedance tensor (except the static shift) is presented. The method proposed uses the Groom & Bailey decomposition of the distortion matrix for the short periods. Three examples are presented: two using synthetic data and one employing real data. These examples show the effect of the galvanic distortion over a regional 2-D/3-D model and the retrieval of the regional transfer functions from the distorted ones.
No takes yet. Share an insight, caveat, or question.
Ledo et al. (1998) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: