Key result
Atorvastatin 80 mg daily reduces carotid stiffness ~38% at 30 days in statin-naive patients.
Why the study?
Few studies have examined the early effects of statins on carotid artery elasticity, a potential surrogate marker of cardiovascular risk.
Does atorvastatin 80 mg daily improve carotid artery elasticity in stroke-free, statin-naive subjects?
Does atorvastatin 80 mg daily improve carotid artery elasticity in stroke-free, statin-naive subjects?
Short-term treatment with high-dose atorvastatin significantly improves carotid elasticity metrics, suggesting its potential as a surrogate endpoint for atherosclerosis risk.
May improve carotid elasticity short-term; leaves open clinical relevance pending larger randomized trials.
BACKGROUND AND PURPOSE: Few studies have examined the early effects of statins on carotid artery elasticity, a potential surrogate marker of cardiovascular risk. This study examined the short-term effects of atorvastatin 80 mg daily on carotid elasticity measured by high-resolution B-mode ultrasound. METHODS: The study included 40 stroke-free and statin-naive subjects older than age 45 (mean age, 70±7 years; 55% men; 64% Caribbean-Hispanic). Outcome measures included carotid stiffness indices at 14 and 30 days after initiation of treatment. The systolic and diastolic diameters of the right common carotid artery were averaged from multiple B-mode imaging frames. Absolute and relative changes of strain [(systolic diameter-diastolic diameter)/diastolic diameter], stiffness (β) [ln (systolic/diastolic blood pressure)/strain], and distensibility (1/β adjusted for wall thickness) from baseline were compared by the repeated measures t test and were considered significant at α=0.05. RESULTS: Baseline mean stiffness was 0.08 (95% confidence interval [CI], 0.06-0.10). It significantly decreased at day 30 to 0.05 (CI, 0.04-0.06; P<0.01). Mean baseline distensibility was 15.25 (CI, 13.18-17.32), increasing significantly at day 30 to 17.23 (CI, 14.01-20.45; P<0.05). An improvement in distensibility of ≥10% from baseline was observed in 29 (73%) subjects. Changes in stiffness and distensibility were maximal among subjects with baseline low-density lipoprotein levels<130 mg/dL. CONCLUSIONS: Short-term treatment with high-dose atorvastatin was associated with improvement in the carotid elasticity metrics. Carotid artery elasticity measured by B-mode ultrasound is a simple noninvasive measure of arterial wall function and may be a useful surrogate end point in clinical trials targeting individuals at increased risk for atherosclerosis.
No takes yet. Share an insight, caveat, or question.
Ratchford et al. (2011) studied Stroke-free and statin-naive (n=40). Atorvastatin was evaluated on Carotid stiffness and distensibility at 14 and 30 days (p=<0.01). Atorvastatin 80 mg daily significantly decreased mean carotid stiffness from 0.08 to 0.05 (P<0.01) and increased distensibility from 15.25 to 17.23 (P<0.05) at 30 days in statin-naive subjects.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: