Flat heat pipe (HP)-phase change material (PCM) hybrid system used for thermal regulation of simulated PV is investigated experimentally. Three PCMs; Rubitherm RT-25 H (RT25), Rubitherm RT-35 H (RT35), and Rubitherm RT-44 H (RT44) coupled with the HP are tested for best cooling system. Impact of using one or two heat sinks compared with PCM only is studied. The results show that RT25 achieves lowest PV temperature, while RT44 achieves highest energy storage. Compared to RT25 and RT44, RT35 is considered the best for PV cooling and PCM energy storage. Including heat sinks reduces PV temperature and melting time and increases energy storage rate.
No takes yet. Share an insight, caveat, or question.
Soliman et al. (2022) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: