Interventional neuroradiology techniques are minimally invasive and allow for superselective drug delivery to specific brain regions. The passage of most agents, however, is impaired by the blood-brain barrier (BBB). Despite its discovery over 40 years ago, hyperosmotic BBB opening (BBBO) remains highly variable, preventing its widespread implementation. Here, we report on a technique that enables the prediction and optimization of the BBBO territory. We found that the microcatheter tip position and the speed of hyperosmolar mannitol injection, both major determinants of the targeted territory, can be modulated in real-time as guided by trans-catheter perfusion MRI.
No takes yet. Share an insight, caveat, or question.
Janowski et al. (2015) studied this question.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: