We have developed the gas-cooling system of a 275 kV, 300 MVA class gas-insulated transformer. In our study model experiments in which gas flow was substituted by water flow equivalently and 2-dimensional numerical flow analyses and network analyses were conducted. In this paper the outline of the development and optimization condition to get high cooling performance in SF/sub 6/ gas-disc winding system of the transformer are presented.
No takes yet. Share an insight, caveat, or question.
Nakadate et al. (1996) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: