Key result
A newly developed portable detection method successfully identified norovirus GII in 56% (9/16) of ambient air samples at a wastewater treatment plant, reaching concentrations up to 3.2 × 10^3 copies/m3.
Observational (n=16)
No
A newly developed portable air sampler successfully detected aerosolized enteric viruses, including norovirus, at a wastewater treatment plant, highlighting potential occupational exposure risks.
May signal occupational airborne virus exposure at wastewater plants; leaves open need for validated portable detection before broader adoption.
The ambient air from wastewater treatment plants has been considered as a potential source of pathogenic microorganisms to cause an occupational risk for the workers of the plants. Existing detection methods for enteric viruses from the air using a liquid as the collection medium therefore require special care to handle on-site. Knowledge accumulation on airborne virus risks from wastewater has been hindered by a lack of portable and handy collection methods. Enteric viruses are prevalent at high concentrations in wastewater; thus, the surrounding air may also be a potential source of viral transmission. We developed a portable collection and detection method for enteric viruses from ambient air and applied it to an actual wastewater treatment plant in Japan. Materials of the collection medium and eluting methods were optimized for real-time polymerase chain reaction-based virus quantification. The method uses a 4 L/min active air sampler, which is capable of testing 0.7–1.6 m3 air after 3–7 h sampling with a detection limit of 102 copies/m3 air in the field. Among 16 samples collected at five to seven locations in three sampling trials (November 2007–January 2008), 56% (9/16) samples were positive for norovirus (NV) GII, with the highest concentration of 3.2 × 103 copies/m3 air observed at the sampling point near a grit chamber. Adenoviruses (4/16), NV GI (6/16), FRNA bacteriophages GIII (3/16), and enteroviruses (3/16) were also detected but at lower concentrations. The virus concentration in the air was associated with that of the wastewater at each process. The results imply that the air from the sewer pipes or treatment process is contaminated by enteric viruses and thus special attention is needed to avoid accidental ingestion of viruses via air.
No takes yet. Share an insight, caveat, or question.
Matsubara et al. (2019) conducted an observational in Airborne enteric viruses (n=16). Portable detection method (HA vortex method) vs. Liquid collector (SKC Biosampler) was evaluated on Detection of norovirus GII in ambient air samples. A newly developed portable detection method successfully identified norovirus GII in 56% (9/16) of ambient air samples at a wastewater treatment plant, reaching concentrations up to 3.2 × 10^3 copies/m3.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: