This is the authors' abstract. We don't add key points for this paper.
Extraction of bone contours from x-ray radiographs plays an important role in joint space width assessment, preoperative planning, and kinematics analysis. We present a robust segmentation method to accurately extract the distal femur and proximal tibia in knee radiographs of varying image quality. A spectral clustering method based on the eigensolution of an affinity matrix is utilized for x-ray image denoising. An active shape model-based segmentation method is employed for robust and accurate segmentation of the denoised x-ray images. The performance of the proposed method is evaluated with x-ray images from the public-use dataset(s), the osteoarthritis initiative, achieving a root mean square error of [Formula: see text] for femur and [Formula: see text] for tibia. The results demonstrate that this method outperforms previous segmentation methods in capturing anatomical shape variations, accounting for image quality differences and guiding accurate segmentation.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Wu et al. (2016) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: