Experimental heat flux measurements are made using both thermocouple and thin film in high-temperature, hypersonic flows. Thermocouple and thin film gages have individually extensively used in relatively high and low enthalpy conditions respectively. this study, three test conditions with varying (intermediate) stagnation enthalpies, Mach Reynolds numbers are created in an expansion tube facility, and temperature histories heat flux measurements obtained using the two gage types are directly compared. performance in terms of survivability, response, uncertainty, and signal-to-noise ratio assessed for both blunt body and flat plate models.