Key result
Novel polymer surgical mitral valve shows stable 1-year hemodynamics, with thromboembolism limited to subtherapeutic INR.
Why the study?
Polymer leaflet material may extend durability and provide stable long-term hemodynamics in surgical mitral valve replacement, but clinical safety and performance data are needed.
Does surgical mitral valve replacement using a novel polymer leaflet valve provide acceptable safety and hemodynamic performance in adult patients requiring mitral valve replacement?
Does surgical mitral valve replacement using a novel polymer leaflet valve provide acceptable safety and hemodynamic performance in adult patients requiring mitral valve replacement?
A novel polymer surgical mitral valve demonstrated an acceptable safety profile and stable hemodynamics at 1 year, with thrombotic events limited to patients with subtherapeutic anticoagulation.
Acceptable 1-year safety and hemodynamics with polymer mitral prosthesis in young rheumatic patients; leaves open durability, thrombotic risk, and anticoagulation needs.
BACKGROUND: Polymer leaflet material may extend the durability of surgical mitral valve replacement (SMVR) to provide stable long-term hemodynamics. The India Mitral Surgical Trial sought to evaluate the safety and performance of a novel polymer leaflet material as part of a surgical mitral valve (MV) prosthesis. OBJECTIVES: In this study, the authors sought to report 1-year outcomes in patients undergoing SMVR for MV disease using the Tria Mitral Valve (Foldax). METHODS: Adult patients requiring MV replacement were enrolled in a prospective single-arm multicenter trial at 8 clinical sites in India from April to November 2023. An independent physician screening committee reviewed each patient for study eligibility before enrollment. Safety events were adjudicated per standard Valve Academic Research Consortium 3 criteria guidelines, and valve performance was assessed by means of echocardiographic and computed tomographic imaging at 30 days and 1 year. Patients were maintained on a vitamin K antagonist (target international normalized ratio: 2.5). RESULTS: and 4.6 ± 1.7 mm Hg, respectively. There were 2 thrombotic events and 3 ischemic strokes, all in patients with subtherapeutic international normalized ratio. CONCLUSIONS: The polymer surgical MV demonstrated an acceptable safety profile and maintained stable hemodynamic performance through 1 year in patients undergoing MV replacement. Further study of this promising polymer leaflet technology is ongoing. (Clinical Investigation for the Foldax Tria Mitral Valve-India; NCT06191718).