This is the authors' abstract. We don't add key points for this paper.
A programmable Josephson voltage standard (PJVS) can be used to generate a precision square wave for induced voltage compensation to measure the mutual inductance between the coils in a joule balance. In this paper, the influence of the transitions between quantized voltages in the synthesized square waves is analyzed in detail. The ratio of the time-integrated value of the transitions to the total waveform is reduced to several parts in 10 4 to improve the measurement accuracy. The influence of different configurations of the integrating digitizer is discussed. The result shows that when the voltages are in a quantum state, the time-integrated agreement between the measured and theoretical differences for two PJVS systems is within 4 × 10 −9 V s V −1 s −1 . For the total time integration of a voltage waveform larger than 2 V s, the combined relative uncertainty is less than 5.9 × 10 −8 V s V −1 s −1 . The result confirms the capability of the PJVS to generate a precision square wave for the joule balance.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2015) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: