Answers are grounded in this paper and cite their sources.
A method is presented for calculating the dissolution rate constant of a borosilicate glass fiber in the lung, as measured in vitro, from the oxide composition in weight percent. It is based upon expressing the logarithm of the dissolution rate as a linear function of the composition. It was found that the calculated dissolution rate constant agreed with the measured value within the variation of the measured data in a set of compositions in which the dissolution rate constant ranged over a factor of 100. The method was shown to provide a reasonable estimate of dissolution over a considerably wider range of composition than what was used to determine the parameters, such as a set of data in which the dissolution rate constant varied over a factor of 100,000. The dissolution rate constant may be used to estimate whether disease would ensue following animal inhalation or intraperitoneal studies.
No takes yet. Share an insight, caveat, or question.
Russell M. Potter Walter Eastes (2000) studied this question.