X-ray diffraction enhanced imaging based on synchrotron radiation has extremely high sensitivity of weakly absorbing low-Z samples in medical and biological fields. This letter is dedicated to a direct reconstruction algorithm for directional-derivative projections of computed tomography of diffraction enhanced imaging. It is a “one-step” algorithm and does not require any restoration processing compared with the current “two-step” methods. The actual values of the sample’s refractive index decrement can be estimated from its reconstruction images directly. The algorithm is proven by the actual experiment at the Beijing Synchrotron Radiation Facility and the reconstructed images are described finally.
No takes yet. Share an insight, caveat, or question.
Huang et al. (2006) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: