Standards stipulate 6-min time interval of averaging for measurements of radio-frequency electromagnetic fields to assess human exposure to non-ionising radiation. Having in mind the base stations of public land mobile systems, the time interval defined in such a way noticeably limits the number of measuring points in practical applications. In this paper, based on the results of measurements in the vicinity of a multisystem base station (Global System for Mobile Communications [GSM], Digital Communication System [DCS] and Universal Mobile Telecommunications System [UMTS]), it was shown that the measurement process can be significantly accelerated by using shorter time intervals of averaging--15 s, 30 s and 1 min. It was found that measurement results differed from the 6-min root-mean-square mean by 10.5 %, 15.9 and 19 %, respectively, while the uncertainty of the measurements was increased by 3.0 %, 3.8 and 4.4 %, respectively. Shorter time-averaging intervals would reduce the total duration of the exposure assessment survey, while not compromising too much on measurement quality.
No takes yet. Share an insight, caveat, or question.
Neskovic et al. (2011) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: