Fatigue properties of magnetorheological elastomer (MRE) samples were investigated based on cis-polybutadiene rubber by using a fatigue test machine. Three MRE samples with iron particles mass fraction of 60%, 70%, and 80% were fabricated, and their properties dependence of three strain amplitudes (50%, 75%, and 100%) were measured. The absolute magnetorheological (MR) effect, storage modulus, and loss modulus of MRE samples after fatigue were evaluated by a modified dynamic mechanical analyzer. The results revealed that MR effect, storage modulus, and loss modulus of MREs containing 80% iron particles depended strongly on the strain amplitudes and the number of cycles, while storage modulus and loss modulus of MREs containing 70% iron particles also depended on the strain amplitudes and the number of cycles but not as strongly as sample which contains 80% iron particles, but the properties of MREs containing 60% iron particles after cyclic deformation were almost independent of the fatigued conditions. In order to investigate the fatigue mechanism of MREs, the sample was carried out with a quasi-static tensile testing and its surface morphology during testing was observed in situ by scanning electron microscopy.