Answers are grounded in this paper and cite their sources.
With the rapid global urbanization, today’s cities are facing an increasing pressure for the treatment of both domestic and industrial wastewaters. In this work, a proof-of-concept of “treating industrial wastewater using the sludge originating from domestic wastewater treatment for urban pollution control” was proposed. After one-step pyrolysis of the excess sludge from domestic wastewater treatment, a metal–carbon composite catalyst with a high H 2 O 2 -producing capacity (432 mg/h/g) was successfully synthesized. By application of the prepared material as a cathode catalyst in an electro-Fenton system, phenol (40 mg/L), a model pollutant in industrial wastewaters, was completely degraded within 40 min at a potential of 0.15–0.35 V (vs reversible hydrogen electrode) without dosing external iron. Meanwhile, approximately 60% of total organic carbon was efficiently removed by the electro-Fenton system within 4 h at 0.25 V, and the hydroxyl radicals were found to be the main oxidation agent for the phenol degradation. More importantly, the phenol removal efficiency remained at a high level (87%) and the released iron was low (0.8 mg/L) even after 10 cycles of reuse. Thus, an efficient and cost-effective integrated system for the treatment of both domestic and industrial wastewaters was successfully developed and validated. The results from this work are useful to establish a new sustainable pollution control scenario.
No takes yet. Share an insight, caveat, or question.
Huang et al. (2018) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: