Thermal stability and the effectiveness of coatings for high-temperature magnets are assessed. Based on several years of experiments and observations, these high-temperature magnets are determined to be metallurgically stable at temperatures up to 550/spl deg/C. These uncoated high-temperature magnets, held at 300/spl deg/C in air for more than three years, had only 0.8%-1.6% losses of their magnetic flux. At temperatures of 400/spl deg/C-550/spl deg/C, a number of different coatings were evaluated, including Al, Ni, Cr, Mo, W, and Cu. After 2630 h of exposure in air at 500/spl deg/C, the degradation of magnetic flux was 0.54% for the magnets coated with Ni, compared to 18.63% for the uncoated magnets. Micrographs and Auger electron spectroscopy were used to study the diffusion of different atoms near the surface and the interface between the coating layer and magnet.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2004) studied this question.