Answers are grounded in this paper and cite their sources.
Sequential exposures of W surfaces to steady-state and pulsed (∼0.5 ms) plasmas have been performed in a linear divertor plasma simulator and a magnetized coaxial plasma gun to investigate effects of D blisters, nano-sized He bubbles, and He-induced W fuzz on surface cracking by pulsed plasma loads. Surface cracks appeared on samples containing D blisters or He bubbles following 10 shots at ∼0.5 MJ/m2 per shot, while a mirror-polished sample with no pre-plasma exposure did not exhibit cracks after similar transient exposures. Note that the cracking is limited to the edge region for a sample with D blisters. This means that the energy density threshold for surface cracking is lowered by the existence of D blisters and, especially, He bubbles. On the other hand, it is found that fuzzy surfaces possess a good resistance to surface cracking, although arcing is prone to occur.
No takes yet. Share an insight, caveat, or question.
Nishijima et al. (2011) studied this question.