Answers are grounded in this paper and cite their sources.
This paper presents a three-dimensional (3-D) hybrid numerical model of the electromagnetic flow meter. Compared to the two-dimensional (2-D) model used before, it is advantageous for the quality of computer simulation, but at the cost of computational burden. Our aim was to compare characteristics of the flowmeter obtained from 2-D and 3-D simulations to check if faster 2-D models can be used for computer-aided design of the device. The results of research show that the 3-D model must be used for optimal design of some parameters of the coil.
No takes yet. Share an insight, caveat, or question.
Michalski et al. (2002) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: