Answers are grounded in this paper and cite their sources.
An effective method for the determination of 49 pesticide residues and 17 mycotoxins in wine by a modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) method and ultrahigh-performance liquid chromatography-tandem mass spectrometry was developed. The target compounds were extracted with 1% (v/v) formic acid-acetonitrile, and no cleanup steps were required. The extracts were separated on a C18 chromatographic column (2.1 mm × 50 mm, 1.7 µm) with acetonitrile and water with 0.2% formic acid solution and ammonium acetate (10 mM) as the mobile phases under gradient elution at a flow rate of 0.2 mL/min. The determination was conducted using electrospray ionization in positive ion mode with multiple reaction monitoring. The analytes were quantified by comparison with matrix-matched standard solutions. The good linearities were obtained in the range of 0.05 to 500.0 µg/kg, and the correlation coefficients were all greater than 0.9935. The average recoveries of the 66 target compounds ranged from 69% to 119%, and the RSDs were in the range of 1% to 10%. The limits of detection were in the range of 0.05 to 20.0 µg/kg. The method was proved to be rapid, selective, sensitive, and stable, and it has been applied to analysis of 64 wine samples.
No takes yet. Share an insight, caveat, or question.
He et al. (2019) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: