Key result
Intraoperative laser Doppler flowmetry and visible light spectroscopy detected a 42% mean StO2 reduction after anastomosis and a significant increase in rHb concentration (P=0.04).
Why the study?
Does intraoperative laser Doppler flowmetry and visible light spectroscopy detect microcirculatory changes in the gastric tube during minimally invasive esophagectomy?
Observational (n=10)
No
Does intraoperative laser Doppler flowmetry and visible light spectroscopy detect microcirculatory changes in the gastric tube during minimally invasive esophagectomy?
Intraoperative laser Doppler flowmetry and visible light spectroscopy are feasible for detecting microcirculatory changes and venous congestion during esophagectomy, potentially identifying risk for anastomotic leaks.
Introduction: Ischemia is considered as the main reason for thoracic gastroesophageal anastomotic leaks after esophagectomy. Microcirculatory monitoring with laser Doppler flowmetry and visible light spectroscopy may provide valuable intraoperative real-time information about the gastric tube’s tissue perfusion and circulation. Patients and Methods: Ten patients with esophageal cancer operated with minimally invasive esophagectomy participated in this single-center, prospective, observational pilot study. A single probe with laser Doppler flowmetry and visible light spectroscopy was used to perform transserosal microcirculation assessment of the gastric tube at predefined anatomical sites during different operation phases. Group comparison and changes were evaluated using the paired sample t -test. Results: A reduction in StO2 was found at all measuring sites after the gastric tube formation compared with the baseline measurements. The mean StO2 reduction from baseline to gastric tube formation and after anastomosis was 16% (range 4%– 28%) and 42% (range, 35%– 52%), respectively. A statistically significant increase in the rHb concentration, representing venous congestion, was detected at the most cranial part of the gastric tube ( P = 0.04). Three patients developed anastomotic leaks. Conclusion: Intraoperative real-time laser Doppler flowmetry and visible light spectroscopy are feasible and may provide insight to microcirculatory changes in the gastric tube and at the anastomotic site. Patients with anastomotic leaks seem to have critical local tissue StO2 reduction and venous congestion that should be further evaluated in studies with larger sample sizes.
No takes yet. Share an insight, caveat, or question.
Safi et al. (2020) conducted an observational in Esophageal cancer (n=10). Laser Doppler flowmetry and visible light spectroscopy vs. Baseline measurements was evaluated on Microcirculatory changes (StO2 reduction and rHb concentration) (p=0.04). Intraoperative laser Doppler flowmetry and visible light spectroscopy detected a 42% mean StO2 reduction after anastomosis and a significant increase in rHb concentration (P=0.04).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: