Background/Aims: : When high-resolution manometry (HRM) intubation is not tolerated or the catheter fails to traverse the lower esophageal sphincter, the test is often abandoned, leaving patients without a diagnosis to guide therapy. Although endoscopic placement of HRM catheters under sedation has been described, no study has directly compared this approach with routine outpatient HRM. This study provides the first direct comparison of sedated endoscopic insertion (EI) versus routine insertion (RI). Methods: : All patients who underwent EI of the HRM catheter between January 2020 and May 2025 were retrospectively reviewed and compared with a contemporaneous cohort who had RI. Each test included the standard protocol of ten 5 mL water swallows followed by a 200 g rice meal. Demographic data, endoscopic technique, sedation levels and manometric diagnoses were evaluated. Esophageal body function was defined in accordance with the Chicago classification version 4.0. No adverse events occurred. Conclusions: : Sedated EI of the HRM catheter enables protocol completion for patients unable to undergo routine testing, filling a key diagnostic gap while delivering manometric results comparable to standard, unsedated studies.
No takes yet. Share an insight, caveat, or question.
Endersby et al. (2026) studied this question.