Key result
Bioprosthetic ring distortion is linked to early calcification and reoperation for structural valve dysfunction.
Why the study?
Valve failure associated with calcification remains a concern with pericardial bioprostheses, and the role of bioprosthesis ring distortion as a risk factor for early calcification was investigated.
Is distortion of the bioprosthesis ring a risk factor for early calcification in patients undergoing aortic valve replacement with a pericardial bioprosthesis?
Observational (n=510)
No
Is distortion of the bioprosthesis ring a risk factor for early calcification in patients undergoing aortic valve replacement with a pericardial bioprosthesis?
Radiologic distortion of the bioprosthesis ring may be a key risk factor and indicator for early bioprosthetic calcification and structural valve failure.
BACKGROUND: As the population ages, bioprosthesis are increasingly being used in cardiac valve replacement. Pericardial bioprosthesis combine an excellent hemodynamic performance with low thrombogenicity, but valve failure associated with calcification remains a concern with these valves. We describe distortion of the bioprosthesis ring as a risk factor for early calcification. METHODS: A total of 510 patients over the age of 70 years underwent isolated aortic valve replacement with the Mitroflow (A12) pericardial bioprosthesis. Thirty two patients (6,2%) have undergone a second aortic valve replacement due to structural valve dysfunction resulting from valve calcification. In all patients a chest radiography and coronary angiography was performed before reoperation. A 64 Multidetector Computed Tomography (MDCT) with retrospective ECG gating study was performed in four patients to evaluate the aortic bioprosthesis. RESULTS: Chest radiography showed in all patients an irregular bioprosthesis ring. At preoperative coronary angiography a distorted bioprosthesis ring was detected in all patients. Macroscopic findings of the explanted bioprostheses included extensive calcification in all specimens. CONCLUSION: There was a possible relationship between early bioprosthetic calcification and radiologic distortion of the bioprosthesis ring.
No takes yet. Share an insight, caveat, or question.
Cereijo et al. (2010) conducted an observational in Aortic valve replacement / Bioprosthetic valve calcification (n=510). Distortion of the bioprosthesis ring vs. Normal bioprosthesis ring was evaluated on Early calcification leading to structural valve dysfunction and reoperation. Radiologic distortion of the bioprosthesis ring was present in 100% of the 32 patients requiring reoperation for early calcification, suggesting a relationship between ring distortion and structural valve dysfunction.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: