The pressure drop, , across a redox flow battery is linked to pumping costs and energy efficiency, making fluid properties of the electrolyte important in scale‐up operations. The at diverse platinized titanium electrodes in Ce‐based redox flow batteries is reported as a function of mean linear electrolyte velocity measured in a rectangular channel flow cell. Darcy's friction factor and permeability vs. Reynolds number are calculated. Average permeability values are: 7.10 × 10−4 cm2 for Pt/Ti mesh, 4.45 × 10−4 cm2 for Pt/Ti plate + turbulence promoters, 1.67 × 10−5 cm2 for Pt/Ti micromesh, and 1.31 × 10−6 cm2 for Pt/Ti felt. The electrochemical volumetric mass transport coefficient, , is provided as a function of . In the flow‐by configuration, Pt/Ti felt combines high values with a relatively high , followed by Pt/Ti micromesh. Pt/Ti mesh and Pt/Ti plate gave a lower but poorer electrochemical performance. Implications for cell design are discussed.
No takes yet. Share an insight, caveat, or question.
Arenas et al. (2017) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:
More from AIChE Journal