Answers are grounded in this paper and cite their sources.
This paper details high time-resolution flow field measurements in a micro-pipe made by a micro digital holographic particle tracking velocimetry (micro-DHPTV) method. The system consists of an objective lens, a high-speed camera and a single high-frequency double pulsed laser. The volume of the system is 409.6 µm × 92 µm × 92 µm. It is illuminated by a laser beam with a pulse length of 58 ns, a resolution time of 100 µs and a repetition rate of 1 kHz. 104 velocity vectors could be obtained instantaneously in the micro-pipe. Particle positions in the three-dimensional field are reconstructed by a computer-generated hologram. The time evolution of a three-dimensional water flow in a micro-pipe of 92 µm inner diameter is obtained successfully using the micro-DHPTV system. The error of reconstruction in the z -direction is evaluated by analysing the traverse of particles on a glass plate and obtaining the velocity error in the z -direction by uncertainty analysis.
No takes yet. Share an insight, caveat, or question.
Satake et al. (2006) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: