Data from a multicentre survey based on three London teaching hospitals on the relative safety and clinical utility of intravenous carotid digital subtraction angiography (DSA) over intra-arterial DSA and conventional carotid angiography are presented. The incidence of stroke during intra-arterial DSA was 0.7% (n = 538) and during conventional angiography was 0.8% (n = 780). The incidence of stroke during intravenous DSA was zero (n = 3710). When it constituted the initial investigation, intravenous DSA achieved a 93.8% replacement value over intra-arterial studies as a whole (n = 474) and 89% replacement value for patients having carotid endarterectomy (n = 99). It was also noted that the installation of DSA equipment at one unit coincided with a sixfold increase in the number of carotid angiographic examinations and an almost threefold increase in carotid endarterectomies.
No takes yet. Share an insight, caveat, or question.
Stevens et al. (1989) studied this question.