Key result
Abdominal imaging during endovascular aneurysm repair (EVAR) was associated with the highest average operator eye dose (7.55 μSv) and patient dose area product (114.8 Gy•cm2) compared to other regions.
Why the study?
There is concern that non-radiology fluoroscopic operators may lack sufficient training regarding radiation exposure and mitigation during vascular and cardiac transcatheter procedures involving overlapping anatomical regions.
How do occupational and patient radiation doses compare across different anatomical regions during fluoroscopically guided cardiac and endovascular procedures?
Observational (n=1,792)
No
How do occupational and patient radiation doses compare across different anatomical regions during fluoroscopically guided cardiac and endovascular procedures?
EVAR and TAVI procedures using digital subtraction angiography are associated with significantly higher radiation exposure to both patients and staff, highlighting the need for enhanced radiation awareness and mitigation.
Answers are grounded in this paper and cite their sources.
Higher EVAR and chest+pelvis doses warrant procedure-specific shielding review; leaves open whether non-radiology training gaps drive excess exposure.
X-ray guided procedures are being performed by an increasing variety of medical specialties. Due to improvements in vascular transcatheter therapies, there is an increasing overlap of imaged anatomy between medical specialties. There is concern that non-radiology fluoroscopic operators may not have sufficient training to be well informed of the potential implications of radiation exposure and mitigation strategies to reduce dose. This was a prospective, observational, single center study to compare occupational and patient dose levels when imaging different anatomical regions during fluoroscopically guided cardiac and endovascular procedures. Occupational radiation dose was measured at the level of the temple of 24 cardiologists and 3 vascular surgeons (n = 1369), 32 scrub nurses (n = 1307) and 35 circulating nurses (n = 885). The patient dose was recorded for procedures (n = 1792) performed in three angiography suites. Abdominal imaging during endovascular aneurysm repair (EVAR) procedures was associated with a comparatively high average patient, operator and scrub nurse dose despite additional table-mounted lead shields. Air kerma was relatively high for procedures performed in the chest, and chest + pelvis. Higher dose area product and staff eye dose were recorded during procedures of the chest + pelvis due to the use of digital subtraction angiography to evaluate access route prior to/during transaortic valve implantation. Scrub nurses were exposed to higher average radiation levels than the operator during some procedures. Staff should be cognizant of the potentially higher radiation burden to patients and exposed personnel during EVAR procedures and cardiac procedures using digital subtraction angiography.
No takes yet. Share an insight, caveat, or question.
Wilson-Stewart et al. (2023) conducted an observational in Fluoroscopically guided vascular and cardiac transcatheter procedures (n=1,792). Endovascular aneurysm repair (EVAR) vs. Chest imaging was evaluated on Operator eye dose (μSv). Abdominal imaging during endovascular aneurysm repair (EVAR) was associated with the highest average operator eye dose (7.55 μSv) and patient dose area product (114.8 Gy•cm2) compared to other regions.
Synapse has enriched 10 related papers. Consider them for comparative context: