This paper proposes a circuit to linearize the signal current and improve the distortion characteristics at the input of a current-mode circuit. Input voltage-to-current (V/I) conversion is carried out by a resistor that connects the signal source and the current input terminal of the current-mode circuit. The signal current flowing into the current-mode circuit through this resistor is distorted because of the signal-dependent voltage change at the current input terminal, and it is linearized by injecting a current that is proportional to the signal-dependent voltage change at the current input terminal, into the same current input terminal of the current-mode circuit. A current-mode sample-and-hold amplifier (SHA) that adopts the proposed scheme was fabricated and a 0.35-mum CMOS process was used to verify the effectiveness of the scheme. It operated from a 2-V supply voltage in the analog part and a 2.5 V in the digital part with a 100-MHz clock and realized a 77- and a 86-dB spurious-free dynamic range values for 0 and -10 dB of full-scale signal current level (plusmn100 muA), respectively, of the 1-MHz signal input. More than a 13-bit equivalent SFDR for -14 to -4 dB of full-scale input was obtained, proving the effectiveness of the proposed scheme at realizing distortionless signal current processing.
No takes yet. Share an insight, caveat, or question.
Sugimoto et al. (2008) studied this question.
Synapse has enriched 2 closely related papers on similar clinical questions. Consider them for comparative context: