The paper presents the results of an experimental study of a cylindrical orifice with the orifice diameter ratioβ = 0.5 and the flow opening length-to-diameter ratioL/d = 1, with hydraulic oil flowing in the DN50 measuring channel. The measurements of the values characterising the oil flow were made in the laminar flow regime, for the Reynolds numbers ranging betweenRe = 100 to 950. Based on the experimental tests, standard flow characteristics were created for four kinematic viscosity values in the range of 13.4–33.3 cSt, for which the average value of the discharge coefficientCin the tested flow rate range ofqv < 0.5 dm3/s was determined.
No takes yet. Share an insight, caveat, or question.
Golijanek-Jędrzejczyk et al. (2023) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: