The PF-1000 plasma focus was modified by adding the cathode disk 3 cm in front of the anode. This modification facilitated the evaluation of neutron energy spectra. Two neutron pulses were distinguishable. As regards the first neutron pulse, it lasted 40 ns during the plasma stagnation and it demonstrated high isotropy of neutron emission. A peak neutron energy detected upstream was 2.46±0.02 MeV. The full width of neutron energy spectra of 90±20 keV enabled to calculate an ion temperature of 1.2 keV. These parameters and a neutron yield of 109 corresponded to theoretical predictions for thermonuclear neutrons.
No takes yet. Share an insight, caveat, or question.
Klír et al. (2011) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: