This study investigated the effects of microbubble contrast agents on the production of premature cardiac contractions in mice exposed to ultrasound. Acoustic exposures consisted of a single pulse of 1.2-MHz ultrasound delivered to the murine heart during diastole. Two contrast agents (Albunex®, Optison®) and two pulse durations (5 ms, 10 μs) were investigated. The threshold for producing a premature contraction with a single 10-μs duration pulse was ∼1 MPa. Using a 5-ms pulse, the threshold with contrast was an order of magnitude less than the threshold without contrast. These results are consistent with cavitation as a mechanism for this bioeffect.