Key result
Platinum coil embolization successfully devascularizes advanced carotid body tumors without post-procedure inflammation.
Why the study?
Resection of Shamblin II and III carotid body tumors is challenging due to significant blood loss and risks associated with liquid embolic agents and coil embolization.
Does superselective targeting of tumor-feeding vessels using platinum-based coils improve sustained devascularization and reduce blood loss in patients with Shamblin II and III carotid body tumors?
Case Report
Does superselective targeting of tumor-feeding vessels using platinum-based coils improve sustained devascularization and reduce blood loss in patients with Shamblin II and III carotid body tumors?
Superselective embolization with platinum-based coils offers an effective method for devascularizing Shamblin II and III carotid body tumors without causing inflammation or requiring carotid artery sacrifice.
Resection of Shamblin II and III carotid body tumors can be challenging owing to the potential for significant blood loss. Prophylactic use of liquid embolic agents poses a risk of inflammatory reactions and nontarget embolization. On the other hand, coil embolization has traditionally been limited to cases involving external carotid artery sacrifice. Herein we demonstrate that superselective targeting of tumor-feeding vessels using platinum based, fully detachable packing coils is effective at sustained devascularization of Shamblin II and III carotid body tumors without subsequent inflammation, allowing for a longer interval between embolization and tumor resection, and potentially reducing blood loss without need for ligation or reconstruction of the internal or external carotid artery.
No takes yet. Share an insight, caveat, or question.
Bellamkonda et al. (2020) conducted a case report in Shamblin II and III carotid body tumors. Superselective carotid body tumor embolization with platinum-based coils was evaluated on Sustained devascularization without subsequent inflammation and reduced blood loss. Superselective embolization using platinum-based coils effectively devascularized Shamblin II and III carotid body tumors without inflammation, potentially reducing blood loss during resection.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: