The filiform corrosion of Mg in NaCl solution was characterized by acoustic emission spectroscopy, measurements of the free-corrosion potential, and optical observations under in situ conditions. Three stages of corrosion were identified: an incubation period, localized attack, and filament propagation. The corrosion mechanisms include the Mg dissolution, the breakdown of hydroxide/oxide surface films, and the burst of gas bubbles. Localized attack and filament propagation are distinguished by a gradual transition from correlated avalanches (wild events) to predominantly stochastic processes (mild events), which still contain some weak avalanche signals. Our approach provides a way to monitor corrosion under in situ conditions.