In this paper, an analysis and calculation of the dc-link current and voltage ripples are presented for a three-phase inverter with unbalanced load. A comparison of the dc-link average and root-mean-square (rms) currents between considering and ignoring high frequency harmonics of the output current is drawn. It is shown that high frequency harmonic currents have little effect on the dc-link current, and therefore, they can be ignored. Based on the symmetrical components method, the dc-link average and harmonic rms currents are derived, and the dc-link voltage ripple is compared between the balanced and unbalanced loads. It can be found that the dc-link current and voltage ripples consist of not only high frequency harmonics but also the double fundamental frequency harmonic, and the voltage ripple is independent of the positive-sequence component and determined by the negative-sequence component, under the unbalanced load. Experimental results are shown to verify the accuracy of the theoretical analysis.
No takes yet. Share an insight, caveat, or question.
Pei et al. (2014) studied this question.