This research developed a novel crack localization technique that employed cross-electromechanical admittance (EMA), and its validity was verified through both analytical simulations and experimental measurements. Initially, an analytical model of the cross-EMA was established based on the transfer matrix method (TMM), and subsequently verified by experimental data and finite element analysis. Using the established model, the cross-EMA signatures were then utilized for crack localization in conjunction with a damage index defined as the correlation coefficient (CC). Furthermore, experimental investigations were carried out on five steel specimens, each of which was instrumented with multiple surface-bonded Lead Zirconate Titanate (PZT) wafers in a distributed manner. A crack with a width of 1.5 mm and a depth of 8 mm was introduced into each specimen to simulate structural damage. Both analytical investigations and experimental research have demonstrated that the cross-EMA signatures exhibit crack localization capabilities and can precisely reflect the local mechanical characteristics of the monitored structure.
No takes yet. Share an insight, caveat, or question.
Yang et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: