Key result
Transseptal antegrade ViV TAVR offers a viable option when standard access routes are unavailable.
Why the study?
A transfemoral, antegrade valve-in-valve TAVR procedure is needed for patients with no other access options, but procedural steps and feasibility were not previously outlined.
Does antegrade transseptal valve-in-valve TAVR provide a safe and feasible procedural option in a high-risk patient with severe aortic stenosis and no alternative access routes?
Case Report (n=1)
No
Does antegrade transseptal valve-in-valve TAVR provide a safe and feasible procedural option in a high-risk patient with severe aortic stenosis and no alternative access routes?
Answers are grounded in this paper and cite their sources.
Antegrade transseptal valve-in-valve TAVR may serve as a viable life-saving alternative for high-risk patients lacking any traditional or alternative vascular access options.
OBJECTIVE: To outline the procedural steps for a transfemoral, antegrade valve in a transcatheter aortic valve replacement procedure in a patient with no other access options. KEY STEPS: Gain femoral venous and arterial access. Position a snare in the ascending aorta. Perform transseptal puncture. From the left atrium, deliver an 0.035-inch wire through the mitral valve and aortic valve into the ascending aorta. Snare the wire in the aorta and create a venous-arterial rail. Deliver a large-bore sheath through the mitral valve. Deliver the transcatheter valve through the sheath over the rail antegrade into the aortic valve. POTENTIAL PITFALLS: Possible complications include inability to deliver the valve across the acute turn from the mitral valve through the aortic valve and damage to the mitral valve chordal structures. TAKE-HOME MESSAGE: Transseptal antegrade transcatheter aortic valve replacement represents a viable treatment option for valve-in-valve patients who are high risk for open surgery and with no other alternative access options.
No takes yet. Share an insight, caveat, or question.
Rossi et al. (2026) conducted a case report in Acute aortic stenosis / Failing bioprosthetic aortic valve (n=1). Antegrade transseptal valve-in-valve TAVR was evaluated on Mean transvalvular pressure gradient. Antegrade transseptal valve-in-valve TAVR was successfully performed in a patient with no traditional access options, reducing the mean transvalvular gradient from 18 mm Hg to 7 mm Hg.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: