Key result
Collar-like plasty for commissural prolapse is associated with zero adverse events and low ~4 mm Hg gradients.
Why the study?
Mitral valve repair for extensive commissural prolapse is complex with variable results and no standard procedure clearly superior for extensive cases.
Observational (n=62)
No
May support collar-like plasty for extensive commissural prolapse; hypothesis-generating and requires prospective validation.
Objectives: Mitral valve repair for extensive commissural prolapse is complex; several methods have been reported with variable results. To restore the leaflet area, we introduced an innovative and effective method rather than a simple folding technique through reconstructing a neocommissure with a "collar-like" plasty technique. Methods: From 2016 to 2021, 62 patients with mitral valve extensive commissural prolapse that received the "collar-like" plasty technique were included. Results: The mean age was 51.7 ± 13.8 years, and 38 (61%) were female. Postplasty transesophageal echocardiography showed the mean transvalvular pressure gradients were 3.8 ± 1.2 mm Hg, end diastolic peak flow velocity was 1.1 ± 0.3 m/s, and coaptation height was 7.9 ± 1.1 mm. During the follow-up period of 3 to 6 months, no deaths or cardiovascular-/valvular plasty-related adverse events occurred. All patients regained their heart function and returned to normal physical activities. Conclusions: The "collar-like" plasty technique can be safely performed for patients with extensive commissural prolapse. Echocardiography revealed that the technique can restore the leaflet area of low transvalvular pressure and flow velocity.
No takes yet. Share an insight, caveat, or question.
Chong et al. (2022) conducted an observational in Mitral valve extensive commissural prolapse (n=62). "Collar-like" plasty technique was evaluated on Postplasty transvalvular pressure gradients (mm Hg). The "collar-like" plasty technique for extensive commissural prolapse resulted in no deaths or adverse events and achieved a mean post-plasty transvalvular pressure gradient of 3.8 mm Hg.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: