Key result
SAFETY disease management adds ~0.4 QALYs over standard care in AF at acceptable cost.
Why the study?
The long-term cost-effectiveness of an atrial fibrillation disease management program compared to standard care was not established from the Australian healthcare system perspective.
RCT
Effect estimate: ICUR $42,513/QALY
Absolute Event Rate: 3.99% vs 3.6%
SAFETY program may be cost-effective at common thresholds; modeling uncertainty leaves open need for prospective trials before routine adoption.
AIM: To assess the long-term cost-effectiveness of an atrial fibrillation disease management program (i.e. the SAFETY program) from the Australian healthcare system perspective. METHODS: A multistate Markov model was developed based on patient-level data from the SAFETY randomized controlled trial. Predicted long-term survival, dependent on hospital admission history, was estimated by extrapolating parametric survival models. Quality-adjusted life years (QALY) and life years (LY) were the primary and secondary outcome measures used to estimate the incremental cost-utility/effectiveness ratio (ICUR/ICER). Both deterministic and probabilistic sensitivity analyses (PSA) were undertaken. RESULTS: The SAFETY program was associated with both higher costs ($94,953 vs. $78,433) and benefits [QALY (3.99 vs 3.60); LY (5.86 vs 5.24)], with an ICUR of $42,513/QALY or ICER of $26,356/LY, compared to standard care. Due to the extended survival, the SAFETY was associated with a greater number of hospitalizations (14.85 vs 11.65) and higher costs for medications ($25,084 vs $22,402) and outpatient care ($12,904 vs $11,524). The cost per hospitalization for an average length of stay, analytical time horizon, and cost of medication are key determinants of ICUR. The PSA showed that the intervention has a 70.4% probability of being cost-effective at a threshold of $50,000/QALY. CONCLUSIONS: The SAFETY program has a high probability of being cost-effective for patients with atrial fibrillation. It is associated with uncertainty that further research could potentially eliminate; implementation with further evidence collection is recommended.
No takes yet. Share an insight, caveat, or question.
Gao et al. (2021) conducted an RCT in atrial fibrillation. SAFETY program vs. standard care was evaluated on Quality-adjusted life years (QALY) (ICUR $42,513/QALY). The SAFETY disease management program for atrial fibrillation yielded 3.99 vs 3.60 QALYs compared to standard care, with an incremental cost-utility ratio of $42,513/QALY.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: