A derivative of the Dixon method, chopper fat suppression, was used in the magnetic resonance imaging evaluation of 40 patients: 37 with suspected optic nerve lesions, predominantly optic neuritis, and three with orbital lesions. In patients with optic neuritis, the technique was sensitive, allowing detection of 29 of 34 visual-evoked-response-confirmed lesions on T2-weighted lipid-suppressed images. There were no false-positive studies. Sensitivity for detection of optic neuritis was 89%; specificity, 100%; and accuracy, 86%. The technique was also useful for depicting inflammatory changes in the orbital apex due to fungal abscess and confirming the fatty nature of an extraconal dermoid tumor. A slight increase in noise and mild accentuation of susceptibility effects at interfaces of air, bone, and brain did not degrade images significantly. The chopper-based technique requires only standard imaging time and has usual spin-echo sensitivity. The results are comparable to short-inversion-time inversion-recovery imaging, without the constraints of sequence limitations or artifacts at fat and water interfaces.
No takes yet. Share an insight, caveat, or question.
Lee et al. (1991) studied this question.