Key result
LAA emptying velocity accurately detects LAA thrombus in AF with an AUC of ~0.91.
Why the study?
A readily available biomarker to definitively exclude left atrial appendage thrombus before PVI or DCCV in AF patients is lacking, and the search for such a biomarker is ongoing.
Observational (n=330)
No
Effect estimate: AUC 0.913 (95% CI 0.870-0.957)
p-value: p=<0.001
LAA emptying velocity may aid noninvasive thrombus detection in AF; leaves open whether it can safely replace TOE before cardioversion.
Patients with atrial fibrillation (AF) undergoing either pulmonary vein isolation (PVI) or direct current cardioversion (DCCV) most commonly undergo transoesophageal echocardiography (TOE) for definite exclusion of a thrombus in the left atrial appendage (LAA).1 As TOE as a semi-invasive procedure is not without risk to the patient and during the current times with a still ongoing SARS-Cov-2 pandemic for the clinician, a definite exclusion of LAA thrombosis before a PVI or DCCV using a readily available biomarker would minimise the risk for the patient and clinician alike. However, as far as now the quest to identify such a biomarker is still ongoing. In their manuscript Almorad et al 2 did compare two cut-offs of D-dimer to exclude LAA thrombus before DCCV. In their study patients did receive a transthoracic echocardiography 6 months before the TOE and D-dimer levels were measured at the day of the DCCV. Two cut-offs were used in the study, the first being 500 ng/mL as suggested by the manufacturer of the test and the second being an age-adjusted value 10 times the patients age.2 The main finding was that both cut-offs were able to identify the 13 patients with LAA thrombus whereby the age-adjusted cut-off had a higher specificity with 66.4% to 50.4% for the standard …
No takes yet. Share an insight, caveat, or question.
Christoph Sinning (2020) conducted an observational in Atrial fibrillation (n=330). Left atrial appendage ultrasound parameters and plasma galectin-3 vs. Patients without left atrial appendage thrombosis was evaluated on Diagnostic value (AUC) of left atrial appendage emptying velocity for left atrial appendage thrombosis (AUC 0.913, 95% CI 0.870-0.957, p=<0.001). Left atrial appendage emptying velocity demonstrated high diagnostic accuracy for detecting left atrial appendage thrombosis in patients with atrial fibrillation, yielding an AUC of 0.913.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: